Kabely
Kabely
Jméno | Recept | Popis |
---|---|---|
Tin Cable | Special uninsulated tin cable which handles up to 5 EU/t (ultra-lowvoltage) have 0.025 loss per block.
Uninsulated cables cannot be painted. Uninsulated cables deal 1 point of damage per 64 EU current rowned down. Most effective tool for cables removal is chainsaw. Used in crafting recipes. |
|
Copper Cable | Uninsulated copper cable which handles up to 32 EU/t (low voltage).
EU loss rate is 0.29 |
|
Insulated Copper Cable |
|
Insulated copper cable which handles up to 32 EU/t (low voltage). Insulation allows the cable to be painted, reduces distance-based energy loss and completely removes electric shock. You can also apply insulation to uninsulated copper cable by putting the uninsulated cable and a single piece of Rubber (shapeless) in a crafting table.
EU loss rate is 0.21 |
Gold Cable | Uninsulated gold cable which handles up to 128 EU/t (medium voltage).
EU loss rate is 0.5 |
|
Single-Insulated Gold Cable |
|
Single-insulated gold cable which handles up to 128 EU/t (mediumvoltage).
EU loss rate is 0.4501 |
Double-Insulated Gold Cable |
|
Double-insulated gold cable which handles up to 128 EU/t (mediumvoltage).
EU loss rate is 0.402 |
HV Cable | Uninsulated HV cable which handles up to 512 EU/t (high voltage) and 2048 EU/t (extreme voltage).
EU loss rate is 1.0 |
|
Single-Insulated HV Cable |
|
Single-insulated HV cable which handles up to 512 EU/t (high voltage) and 2048 EU/t (extreme voltage).
EU loss rate is 0.949 |
Double-Insulated HV Cable |
|
Double-insulated HV cable which handles up to 512 EU/t (high voltage) and 2048 EU/t (extreme voltage).
EU loss rate is 0.9 |
Triple-Insulated HV Cable |
|
Triple-insulated HV cable which handles up to 512 EU/t (high voltage) and 2048 EU/t (extreme voltage).
EU loss rate is 0.8 Although in-game it currently lists "4xInsulated", that is incorrect as you are adding a layer of insulation each time, not doubling the insulation each time. It is actually "3xIns" and should get renamed eventually in some future patch. |
Glass Fibre Cable |
|
Special glass fibre cable which handles up to 512 EU/t (high voltage). It is the only kind of uninsulated cable which can be painted and gives no electric shock. Glass fibre cable is useful for long-distance wiring, since it has the smallest energy loss of all kinds of cable - 1 EU every 40 blocks (0.025 EU per block). |
Detector Cable | Outputs Redstone current when powered, support up to 512 EU flow(cannot be placed on HV lines).
EU loss rate is 0.5 (Since v1.62 this is no longer a viable cable option to replace glass fibre!) |
|
Splitter Cable | Prevents the transfer of EU while being powered by Redstone, support up to 512 EU flow.
EU loss rate is 0.025 |